LIC Hybrid Supercapacitor Modules
Millisecond backup power for every AI rack
Racks now draw 132–142 kW and shift load in milliseconds while the grid answers in minutes. CapStack laser-welds LIC modules that bridge that gap — cell to busbar to test report.
Why LIC, in numbers
The cell economics of ride-through

Spotlight · RackBridge 48V
Spec, not slogans
The module your power shelf talks to: welded busbars instead of cabling, active balancing across all 16 cells, and a test report with every serial number.
| Rated voltage | 48.6 V class (16S) |
|---|---|
| Capacitance class | 166 F (±5% sorted) |
| Continuous current | 130 A (25 °C, natural air) |
| Surge current class | > 500 A (< 5 s) |
| Balancing | Active / passive, module-to-module auto |
| Telemetry | Per-cell voltage + NTC, CAN 2.0B |
| Operating temp | −40 … +65 °C |
| Alarms | Over-charge / over-discharge / over-temp, error output |
How we build
From spec to shipment
Spec review
Send rack power profile and ride-through window. We map it to cell count, capacitance and ESR targets.
Cell selection & sorting
Tier-1 LIC cells, C/ESR dual-parameter measured, binned to a ±5% module window on our sorting line.
Sample & qualification
First articles with balancing, structure and connector options. Full test data ships with samples.
Mass production
Laser welding, BMS assembly, aging and 100% final test. Standard lead time 4–6 weeks.
Industries
Where the milliseconds matter
AI Data Center
Rack-level ride-through and peak shaving for GB300-class training clusters.
Explore →Smart Grid
Voltage-sag ride-through and power quality for substations and sensitive plants.
Explore →Wind Pitch
Safety feathering at −40 °C when the grid drops — no cold-soaked batteries.
Explore →Railway
Regenerative braking recovery rated for hundreds of cycles a day.
Explore →Port & Crane
Potential-energy recovery that flattens peak demand on every lift cycle.
Explore →Automotive 48V
Safety-redundancy power for steering, braking and ECUs through cranking dips.
Explore →Field posture
Built for integrators who get audited
48V module fleet qualified for a hyperscaler-tier rack program, targeting a 15-year design-life class in a sealed shelf.
±5% fleet consistencyPitch-backup modules specified for cold-site fleets where lead-acid fails below −20 °C and access windows are short.
−40 °C crankingSupercap bridge modules replacing battery strings for seconds-to-minutes ride-through ahead of genset start.
500k+ cycle class
Start the conversation
Tell us your rack power and ride-through target.
Every RFQ answered within 48 hours — with a cell count, a capacitance number and a lead time, not a brochure.